描述
POTTER & BRUMFIELD SDAS-01-7Y2S1024:这块交流欠电流感应继电器,那是工业控制里的“老将”!核心功能:非接触式感应交流电流,监测其是否低于设定阈值,一旦发生,立即触发DPDT继电器输出。感应电流范围:1.5-15A AC,控制电压:24VAC/DC,输出触点:2 Form C (DPDT)。专治电机空载、负载脱落等“疑难杂症”。别瞅了,原厂停产货,售后照样搞定,咱家就是你搞定电气保护的靠山,没毛病!
POTTER & BRUMFIELD SDAS-01-7Y2S1024 产品概述
POTTER & BRUMFIELD SDAS-01-7Y2S1024 是一款经典的交流电流感应继电器,由著名的Potter & Brumfield公司(现在隶属于TE Connectivity)生产。这玩意儿可不是随便拿个万用表就能替代的,它在工业电气控制系统中扮演着“电流哨兵”的角色,主要就是为了监测交流电流的欠载或丢失情况。想想看,一台电机要是空转了,或者皮带断了,电流会急剧下降,这时候 POTTER & BRUMFIELD SDAS-01-7Y2S1024 就能派上大用场了。
这款模块采用非接触式感应原理,你不需要把它串联到主电路里,只需让被测量的电线穿过它提供的感应孔就行了,真正做到了“零插入损耗”,对主电路毫无影响。它内部集成了固态感应电路,能精确检测1.5到15安培的交流电流。一旦监测到电流低于你设定的阈值,内部的双刀双掷(DPDT)继电器就会动作,给你发出信号或者直接切断电源,保护你的设备不被“玩坏”。型号里的“7”就代表它是欠电流(undercurrent)感应模式,而“1024”则指明了它的控制电源是24VAC/DC。别看它是个“老家伙”,在很多要求高可靠性和简洁的系统里,POTTER & BRUMFIELD SDAS-01-7Y2S1024 至今依然发挥着重要作用。
POTTER & BRUMFIELD SDAS-01-7Y2S1024
POTTER & BRUMFIELD SDAS-01-7Y2S1024 技术规格
参数名称 | 参数值 |
产品型号 | POTTER & BRUMFIELD SDAS-01-7Y2S1024 |
制造商 | Potter & Brumfield (隶属于TE Connectivity) |
产品类型 | 交流欠电流感应继电器 |
感应电流范围 | 1.5 – 15 安培 AC |
控制电压 | 24 VAC (50/60 Hz) / 24 VDC (±10%) |
感应模式 | 欠电流 (Undercurrent) |
设定点调节 | 通过电位器可调 |
设定点偏差 | 工作温度范围内 ±25% |
内部继电器触点 | 2 Form C (DPDT) |
触点额定值 | 2A @ 28VDC, 1A @ 120VAC (阻性负载) |
时间延迟 (欠电流) | 典型 350 ms,最小 200 ms (从欠电流发生后) |
插入损耗 | 零插入损耗 (感应式) |
功耗 | 1.7W 或 1.7VA @ 24VAC |
工作温度范围 | -25°C 至 +70°C |
储存温度范围 | -40°C 至 +85°C |
安装方式 | 插座式 (适用于KUP系列3极插座) |
防护等级 | 防尘罩外壳 |
重量 | 约 90g |
主要特点和优势
老哥,说起 POTTER & BRUMFIELD SDAS-01-7Y2S1024 这块板子,那可真有两把刷子!它能在工业控制里站稳脚跟,靠的就是实实在在的本事。
首先,它最大的特点就是 非接触式电流感应。你根本不需要费劲去切断主电源回路,或者增加任何电阻去测量电流,直接让被监测的电线穿过它的感应孔就行了。这种零插入损耗 (Zero Insertion Loss) 的设计,简直太省心了!它不会对你的主电路造成任何额外的功耗或者压降,这就保证了你设备的原始性能不受影响,而且安装起来那叫一个方便快捷,省时省力。
其次,POTTER & BRUMFIELD SDAS-01-7Y2S1024 的欠电流检测功能非常实用。在工业现场,很多设备,特别是电机,最怕的就是空载或者负载突然脱落。你想啊,一个泵在抽水,突然没水了,电机还在空转,电流肯定会骤降,这时候要是没个保护,电机轴承、密封件可能就“报废”了。这玩意儿就能帮你及时发现这些异常,提前发出警报或者直接停机,有效保护你的电机和机械设备不被“烧毁”或损坏。它的检测范围是1.5到15安培,而且可以通过板子上的电位器(Potentiometer)灵活调整设定点 (Adjustable Set Point),适配性非常强。
再来就是它的内置时间延迟 (Built-in Time Delay)。咱们知道,电气信号有时候会有些短暂的波动,或者设备启动时电流会有个瞬间的冲击。要是没有延迟,这种继电器就可能“误报”频繁跳闸,那不得把人烦死?POTTER & BRUMFIELD SDAS-01-7Y2S1024 就很聪明,它有个典型的350毫秒延时,能自动过滤掉这些瞬时干扰,确保只有真正的、持续的欠电流情况才会触发报警,这大大提升了系统的稳定性和抗干扰能力 (Anti-interference Ability),让你的设备运行起来更踏实,更可靠。最后,它输出的还是DPDT (Double Pole Double Throw) 继电器触点,这给了你丰富的控制选择,你可以用来报警,也可以用来切断回路,或者同时控制两路不同的信号,玩儿法多样!
English Content:
Alright, folks! Let’s talk about the POTTER & BRUMFIELD SDAS-01-7Y2S1024. This isn’t just any component; it’s a veteran AC Undercurrent Sensing Relay designed for robust industrial applications. What truly sets this unit apart is its non-contact inductive sensing capability. You don’t need to break your main power circuit; simply pass the current-carrying wire through its sensing window. This provides zero insertion loss, meaning no added resistance or power consumption to your primary circuit, which is a huge advantage for system efficiency and simplified installation.
The SDAS-01-7Y2S1024 is specifically engineered to detect when the AC current in a monitored circuit drops below a user-adjustable threshold within a 1.5 to 15 Amp range. This makes it an indispensable tool for applications where underload conditions could lead to equipment damage, such as dry-running pumps, broken belts on motors, or failed heating elements. Its adjustable set point allows for precise calibration to specific application requirements, ensuring optimal protection.
Furthermore, the integrated time delay (typically 350ms) is a critical feature, preventing nuisance tripping from momentary current fluctuations or startup transients. This enhances the overall system stability and reliability. When an undercurrent condition persists beyond this delay, the internal DPDT (Double Pole Double Throw) relay activates, providing versatile output contacts for alarms, shutdowns, or interfacing with your control systems. Despite being an older, now obsolete model, its robust design and straightforward functionality continue to make it a reliable choice for maintaining the integrity and safety of industrial machinery.
应用领域
老铁,你别看 POTTER & BRUMFIELD SDAS-01-7Y2S1024 是个欠电流感应继电器,但它在工业现场的应用那可真不少,尤其是在那些对设备保护和运行状态监测有要求的场合。
首先,最常见的肯定是电机和泵的保护。你想啊,一个水泵万一没水了,或者堵塞了,电机电流肯定会下降,如果这时候电机还空转,那电机轴承和机械密封件可就遭殃了。有了 SDAS-01-7Y2S1024,它能及时感应到这种电流下降,然后给你发信号或者直接把电机停掉,防止电机过热、空载损坏,延长设备寿命。
其次,在加热器和照明电路的监测上,它也很有用。比如电加热炉里的加热棒,要是某个加热棒断了,总电流肯定会下降。POTTER & BRUMFIELD SDAS-01-7Y2S1024 就能发现这个异常,及时提醒你进行维护,确保加热效果和生产效率。同样的道理,在大型工厂的照明系统里,也能用来监测线路是否有断路或者大量灯泡损坏的情况。
再来,像一些输送带、搅拌机等机械设备,如果出现皮带打滑、物料堵塞导致负载减轻,或者甚至空转,电流也会发生变化。这时候,POTTER & BRUMFIELD SDAS-01-7Y2S1024 就能作为一种过程监测的工具,通过电流变化判断设备是否正常运行,从而避免更大规模的故障或者产品质量问题。虽然它现在是停产产品,但在许多存量设备和特定改造项目中,它依然是经济且可靠的解决方案。
POTTER & BRUMFIELD SDAS-01-7Y2S1024
相关产品
既然提到了 POTTER & BRUMFIELD SDAS-01-7Y2S1024,那咱就得说说它的“兄弟姐妹”和一些现代“替代品”了。
POTTER & BRUMFIELD SDAS-01-8Y2S1024:这是同一个系列的产品,但功能是过电流感应,也就是说,它是在电流超过设定值时触发动作,和咱们说的欠电流是“反着来”的。
POTTER & BRUMFIELD SDAS-01 系列其他型号:这个系列还有不同控制电压(比如SDAS-01-7Y2S1120 是120VAC控制电压,SDAS-01-7Y2S1240 是240VAC控制电压)或者不同触点配置的型号。
OMRON K8AK-PM 系列:这是欧姆龙的电机电流监测继电器,功能上与SDAS-01系列相似,提供过流、欠流和电流窗口检测,是现代设备升级时常考虑的替代品。
CARLO GAVAZZI DIA53 系列:卡罗伽瓦齐的三相电流监测继电器,功能更全面,除了过欠流,还能监测相序、相不平衡等。
SCHNEIDER ELECTRIC RM35JA 系列:施耐德电气的电流控制继电器,同样提供过流、欠流检测,常用于电机保护和负载监测。
PHOENIX CONTACT EMD-FL 系列:菲尼克斯的设备监测继电器,也包括电流监测功能,体积更紧凑,适用于导轨安装。
ABB CM-PCE 系列:ABB的电流监测继电器,功能多样,提供多种电流范围和控制电源选项。
这些现代产品通常在功能、精度、尺寸和通信接口上有所升级,但核心的电流监测和继电器输出功能是相似的,选择时得根据具体应用需求来定。
安装前准备:老哥,装 POTTER & BRUMFIELD SDAS-01-7Y2S1024 这玩意儿,你可得先“敬畏”电力,安全是第一位的!务必确保你要操作的电路已经完全断电,并且通过验电确认无电压。检查你的控制柜是否有合适的空间,通常它需要一个KUP 3极插座来安装。确认你的控制电源是24VAC/DC,别搞错了电压把设备烧了。最后,检查被测量的电线是否能顺利穿过传感器的感应孔,确保没有异物或者阻碍。
维护建议:POTTER & BRUMFIELD SDAS-01-7Y2S1024 这东西皮实耐用,但“三分靠修,七分靠养”!定期检查它的外部是否有灰尘堆积,尤其是感应孔周围,保持清洁能让它更灵敏。偶尔检查一下接线端子是否松动,连接不良可是电气故障的常见原因。由于它是继电器输出,长时间运行后触点可能会有磨损,如果发现它动作不灵敏,或者触点烧蚀,那可能就得考虑更换了。